LUMIX Xenon Flash Illuminators for traffic control

Summary of comparative features FR20-2 - FR60-2 - FR80

(preliminary for the FR80)


     
FR20
FR60

FR80
PRELIMINARY

unit
Stored energy
170
475
600
Joule
Guide number, meters, 100 ISO
32
60
82
(1)
Maximum distance, 400 ISO, f2.8
22
42
58
meter (1)
Flash duration
< 220
< 300
< 260
µs (1)
Emission peak power
280
350
400
kW
Minimum interval between 2 shots
0.02
0.02
0.01
second
Maximum number of shots in a 100 Hz burst
--
--
4
shot (2)(3) 
Maximum number of shots in a 50 Hz burst
2
3
4
shot (2)(3)
Maximum number of shots in a 5 Hz burst
2
4
5
shot (2)(3) 
Maximum number of shots in a 1 Hz burst
4
6
16
shot (2)(3) 
Maximum repetition rate, 24/24h
0.25
0.33
0.7
Hz (2)(3) 
Conversion power (nominal value at 20°C)
30
45
55
Watt (3) 
Peak supply current (12V version)
2
4
5
Ampere
Stand-by consumption (12V version)
< 1.5
< 1.5
5
Watt
Built-in fuse (12V version)
3
5
8
Amp (Time-lag T)
Reverse polarity protection (12V version)
yes, -16V
yes, -16V
yes, -16V
     
Operating voltage
+10...+16V
+10...+16V
+9...+16V
     
Body size
86x115x151
110x145x210
170x170x250
mm
Weight, ready for use, with metal case
1.2
2.7
5
kg
Weight, ready for use, without metal case
0.6
1.4
3
kg
Lifespan of the lamp
75 000
100 000
100 000
shot (2)(4)(5)     
Operating ambient temperature
-20...+55
-20...+55
-30...+60
°C
Autotest programme setting
no
yes
yes
     
Programmed sequences of flashes
no
yes (optional)
yes ( optional)
     
Specific software for red lights
no
yes
yes
optional
Controllable by feed-back of light
no
no
yes
     
4-bits input control
no
no
yes
     
3-bits output control
no
no
yes
     
Thermal safety
no
yes
yes
     



Notes :

(1) given at rated energy, and for pictures of vehicles, slightly under exposed in order to reduce the adverse effect of highlights like reflections on shiny parts.

(2) given at rated energy.

(3) at 20° C

(4) given at 30% loss of light emission.

(5) at 01.Hz average repetition rate.

Back to Lumix webpage for traffic control