FR20
|
FR60
|
|
unit
|
| Stored energy |
170
|
475
|
600
|
Joule
|
| Guide number, meters, 100 ISO |
32
|
60
|
82
|
(1)
|
| Maximum distance, 400 ISO, f2.8 |
22
|
42
|
58
|
meter (1)
|
| Flash duration |
< 220
|
< 300
|
< 260
|
µs (1)
|
| Emission peak power |
280
|
350
|
400
|
kW
|
| Minimum interval between 2 shots |
0.02
|
0.02
|
0.01
|
second
|
| Maximum number of shots in a 100 Hz burst |
--
|
--
|
4
|
shot (2)(3)
|
| Maximum number of shots in a 50 Hz burst |
2
|
3
|
4
|
shot (2)(3)
|
| Maximum number of shots in a 5 Hz burst |
2
|
4
|
5
|
shot (2)(3)
|
| Maximum number of shots in a 1 Hz burst |
4
|
6
|
16
|
shot (2)(3)
|
| Maximum repetition rate, 24/24h |
0.25
|
0.33
|
0.7
|
Hz (2)(3)
|
| Conversion power (nominal value at 20°C) |
30
|
45
|
55
|
Watt (3)
|
| Peak supply current (12V version) |
2
|
4
|
5
|
Ampere
|
| Stand-by consumption (12V version) |
< 1.5
|
< 1.5
|
5
|
Watt
|
| Built-in fuse (12V version) |
3
|
5
|
8
|
Amp (Time-lag T)
|
| Reverse polarity protection (12V version) |
yes, -16V
|
yes, -16V
|
yes, -16V
|
|
| Operating voltage |
+10...+16V
|
+10...+16V
|
+9...+16V
|
|
| Body size |
86x115x151
|
110x145x210
|
170x170x250
|
mm
|
| Weight, ready for use, with metal case |
1.2
|
2.7
|
5
|
kg
|
| Weight, ready for use, without metal case |
0.6
|
1.4
|
3
|
kg
|
| Lifespan of the lamp |
75 000
|
100 000
|
100 000
|
shot (2)(4)(5)
|
| Operating ambient temperature |
-20...+55
|
-20...+55
|
-30...+60
|
°C
|
| Autotest programme setting |
no
|
yes
|
yes
|
|
| Programmed sequences of flashes |
no
|
yes (optional)
|
yes ( optional)
|
|
| Specific software for red lights |
no
|
yes
|
yes
|
optional
|
| Controllable by feed-back of light |
no
|
no
|
yes
|
|
| 4-bits input control |
no
|
no
|
yes
|
|
| 3-bits output control |
no
|
no
|
yes
|
|
| Thermal safety |
no
|
yes
|
yes
|
|